Lifecycle & ControlsCalibration & Verification

Measurement & Equipment Confidence

Calibration & Verification

Building Confidence in Laboratory Measurements

Learn how calibration, verification, reference standards, traceability, acceptance criteria, and documented results work together to establish confidence in laboratory measurements.

REFERENCE
MEASUREMENT
COMPARISON
EVALUATION
DOCUMENTED RESULT
MEASUREMENT CONFIDENCE

Why Calibration & Verification Matter

Measurement Confidence

Establishes that instruments and methods produce reliable, trustworthy results.

Traceability

Links measurements to recognised references through a documented, unbroken chain.

Defined Acceptance Criteria

Provides clear, objective standards for evaluating whether results are acceptable.

Reliable Results

Supports consistent, reproducible measurements across instruments, sites, and time.

Documented Evidence

Creates the objective evidence required for regulatory compliance and quality systems.

Lifecycle Control

Maintains measurement confidence throughout the full equipment lifecycle.

Calibration vs Verification

Related but distinct activities — not interchangeable terms

Calibration

Core Question

How does an instrument's indication or measurement relate to an appropriate reference or standard under defined conditions?

Primary Focus

Measurement relationship, measurement confidence, reference standards, traceability where applicable, and documented calibration results.

Typical Output

Calibration results, calibration certificate, or calibration record.

Calibration is NOT simply adjustment. Adjustment may occur separately when appropriate.

Verification

Core Question

Does the equipment, instrument, method, or characteristic meet specified requirements or defined acceptance criteria?

Primary Focus

Confirmation against defined requirements or acceptance criteria.

Typical Output

Verification result / documented confirmation.

CALIBRATION ≠ VERIFICATION ≠ ADJUSTMENT — but they may relate

The Calibration Workflow

DEFINE MEASURAND / REQUIREMENT
SELECT APPROPRIATE REFERENCE
CONFIRM REFERENCE STATUS
ESTABLISH TEST CONDITIONS
AS-FOUND MEASUREMENTS
COMPARE / EVALUATE
ADJUSTMENT IF APPLICABLE
AS-LEFT MEASUREMENTS IF APPLICABLE
DOCUMENT RESULTS
REVIEW / RELEASE

The exact sequence depends on the instrument, calibration method, applicable procedure, and requirements.

Reference Standards

REFERENCE STANDARD
USED FOR COMPARISON
SUPPORTS MEASUREMENT RELATIONSHIP
DOCUMENTED STATUS
MEASUREMENT CONFIDENCE

Reference Standard

A standard used as a basis for comparison during calibration.

Reference Equipment

Instruments or devices used to provide the reference measurement.

Certified Reference Material

Where applicable, a material with certified property values for use in calibration.

Calibration Status

The current calibration state of the reference — valid, expired, or under review.

Identification

Unique identification of the reference standard used and its traceability information.

Range / Capability

The measurement range and capability of the reference relevant to the calibration.

Environmental Requirements

Where applicable, the environmental conditions required for valid reference use.

Not all reference types apply to every calibration.

Traceability

Metrological traceability is supported by a documented unbroken chain of calibrations, each contributing to measurement uncertainty.

LABORATORY INSTRUMENT

Your measurement device

calibrated against

WORKING / REFERENCE STANDARD

Used for the calibration

calibrated against

HIGHER-LEVEL REFERENCE(S)

Calibrated against a higher standard

calibrated against

RECOGNISED REFERENCE / SI RELATIONSHIP

Where applicable

Tolerance & Acceptance Criteria

Tolerance / acceptance criteria and measurement uncertainty are related considerations but are not the same concept.

MEASURED RESULT
DEFINED ACCEPTANCE CRITERIA
EVALUATION
ACCEPT / INVESTIGATE / ACTION AS APPLICABLE

Acceptance criteria are defined based on the specific instrument, method, and applicable requirements — universal tolerance values are not appropriate.

As-Found vs As-Left

AS-FOUND

Instrument condition and results before any adjustment or corrective intervention.

EVALUATION
ADJUSTMENT / ACTION where applicable

AS-LEFT

Instrument condition and results after applicable adjustment or intervention.

Preserving both as-found and as-left results is important for understanding equipment performance history and assessing the potential impact of any out-of-tolerance condition.

Calibration Results

Reference ValueIndicated ValueDifference / ErrorAcceptance CriteriaResult
100.00 g100.02 g+0.02 g± 0.05 gPASS
200.00 g199.97 g−0.03 g± 0.05 gPASS
500.00 g500.08 g+0.08 g± 0.05 gINVESTIGATE

Illustrative example — not actual calibration data.

Measurement uncertainty is an additional consideration where applicable.

Measurement Uncertainty

Every measurement result carries an associated uncertainty — a range within which the true value is expected to lie.

MEASUREMENT RESULT
UNCERTAINTY CONTRIBUTIONS
MEASUREMENT UNCERTAINTY
CONFIDENCE / INTERPRETATION

This is an introductory overview. A detailed Technical Guide on measurement uncertainty evaluation will be available in a future update.

Calibration Interval

Calibration interval is not simply an arbitrary fixed number. It should be established and reviewed based on multiple factors.

Factors to Consider

Equipment Type
Manufacturer Information
Historical Performance
Frequency of Use
Criticality
Environmental Conditions
Previous Calibration Results
Maintenance / Repairs
Risk
Applicable Procedures / Requirements

Interval Review Process

REVIEW INFORMATION
ESTABLISH / REVIEW INTERVAL
MONITOR PERFORMANCE
ADJUST INTERVAL WHERE JUSTIFIED

No single universal calibration interval applies to all instruments or all organisations.

Out-of-Tolerance (OOT)

CALIBRATION RESULT
OUTSIDE DEFINED ACCEPTANCE CRITERIA?
YES → DOCUMENT
ASSESS EQUIPMENT
ASSESS POTENTIAL IMPACT
INVESTIGATE
CORRECTIVE ACTION AS APPLICABLE
RECALIBRATE / VERIFY
DOCUMENT CONCLUSION

The exact investigation and impact assessment depend on the organisation's procedures and applicable requirements.

Calibration Certificate / Record

Typical elements — exact certificate content depends on the calibration activity and applicable requirements.

Calibration Certificate / Record
Equipment Identification
Calibration Date
Calibration Method / Procedure
Reference Standards Used
Reference Standard Identification
Calibration Status (where applicable)
Environmental Conditions (where relevant)
Measurement Points
Results
Acceptance Criteria (where applicable)
Measurement Uncertainty (where reported)
As-Found Results
As-Left Results (where applicable)
Statement / Result
Technician / Reviewer
Traceability Information (where applicable)
Next Due / Interval Information (where applicable)

Calibration, Verification, Qualification & Validation

Related but distinct activities — not interchangeable terms

Calibration

Core Question

How does an instrument's indication relate to an appropriate reference under defined conditions?

Primary Focus

Measurement relationship, reference standards, traceability, documented results.

Typical Evidence / Output

Calibration results, certificate, or record.

Verification

Core Question

Does the equipment, instrument, method, or characteristic meet specified requirements or acceptance criteria?

Primary Focus

Confirmation against defined requirements or acceptance criteria.

Typical Evidence / Output

Verification result / documented confirmation.

Qualification

Core Question

Is the equipment suitable for its intended use and does it perform as required?

Primary Focus

Installation, operational, and performance evidence for equipment fitness for purpose.

Typical Evidence / Output

IQ, OQ, PQ documentation and qualification report.

Validation

Core Question

Does the process, method, or system consistently produce results meeting predefined requirements?

Primary Focus

Documented evidence that a process or system consistently delivers the intended result.

Typical Evidence / Output

Validation protocol, report, and ongoing monitoring.

Connection to Equipment Lifecycle

01SELECT / ACQUIRE
02INSTALL
03QUALIFY
04CALIBRATE & VERIFY
05USE
06MONITOR
07MAINTAIN
08CALIBRATE / VERIFY AGAIN
09CHANGE / REPAIR
10ASSESS IMPACT
11REQUALIFY / RECALIBRATE WHERE REQUIRED
12CONTINUED CONTROL